Vol. 59 No. 4
April 2007
Distributed-temperature sensing (DTS) coupled with a temperature/pressure simulator was used to determine flow profiles from multilayered commingled reservoirs in gas wells. Quantitative individual-layer contributions to gas-flow rates and main water entries were determined, which in turn, helped engineers evaluate production conditions, track individual-layer recovery, identify problem zones, and plan remedial actions.
View a Synopsis of SPE 103097 published